Biodiesel Spectrocertified® Testing Standards

Biodiesel Fuel Standards and Chemicals

Calibration standards and chemicals in accordance with the methodology indicated by ASTM D5453, D6584, D6751 and D2887; and DIN EN 14105, 14214 and 14538; and ACOS Method CA 36-87; and UOP 389 and 391 for testing biodiesel fuels.

Biodiesel Fuel Sulfur Sets
(ASTM D5453 Method)

Cat. No. Description
S(BIO)6L DBS in Biodiesel Fuel Set; Low Concentration Range. 6 Standards per set; 100 ml of each. Concentrations: 0.0, 5, 10,15, 20 and 25 PPM S
S(BIO)6H DBS in Biodiesel Fuel Set; High Concentration Range. 6 Standards per set; 100 ml of each. Concentrations: 0.0, 200, 400, 600, 800 and 1000 PPM S
Image of Biodiesel Free and Total Glycerin Sets
Order Now

Biodiesel Free and Total Glycerin Sets
(ASTM D6584 or DIN EN14105 Methods)

Cat. No. Description
D6584-MIX Five standards containing the four glycerin components in pyridine in sealed ampoules as described in the methodology; one 5 ml quantity of 1000 ng/µL butanetriol Internal Standard #1 in pyridine in a sealed ampoule; one 5 ml quantity of 8000 ng/µL tricaprin Internal Standard #2 in pyridine in a sealed ampoule; one 5 ml quantity of N-methyl-N-trimethylsilyltri-fluoro aceaminde (MSTFA) silyating reagent in a capped vial; and one 250 ml amber bottle of heptane.
D6584-SS One 5 ml quantity of 500 ng/uL glycerin in pyridine in a sealed ampoule; one 5 ml quantity of 5000 ng/µL 1-Mono (cis-9-octadecanoyl)-rac-glycerol (momoolein) in pyridine in a sealed ampoule; one 5 ml quantity of 500 ng/µL 1,3-Di(cis-octadecanoyl) glycerol (dialen) in pyridine in a sealed ampoule; one 1,2,3-Tri (cis-octadecanoyl) in pyridine in a sealed ampoule; one 5 ml 1000 ng/µL butanetriol Internal Standard #1 in pyridine in a sealed ampoule; one 5 ml quantity of 8000 ng/µL tricaprin Internal Standard #2 in pyridine in a sealed ampoule; one 5 ml quantity of N-methyl-N-trimethylsilyltri-fluoro aceaminde (MSTFA) silyating reagent in a capped vial; and one 250 ml amber bottle of heptane.
D6584-50KIT Multi-Run Kit: Adequate quantities for 50 GC runs; one 5 ml sealed ampoule of Internal Standard #1; one 5 ml sealed ampoule of Internal Standard #2; and one 5 ml sealed ampoule of MSTFA.
D6584-100KIT Multi-Run Kit: Adequate quantities for 100 GC runs; one 10 ml sealed ampoule of Internal Standard #1; one 10 ml sealed ampoule of Internal Standard #2; and one 10 ml sealed ampoule of MSTFA.
D6584-250KIT Multi-Run Kit: Adequate quantities for 250 GC runs; one 25 ml sealed ampoule of Internal Standard #1; one 25 ml sealed ampoule of Standard #2; and one 25 ml sealed ampoule of MSTFA.
D6584-500KIT Multi-Run Kit: Adequate quantities for 500 GC runs; one 50 ml sealed ampoule of Internal Standard #1; one 50 ml sealed ampoule of Internal Standard #2; and one 50 ml sealed ampoule of MSTFA.
Image of Biodiesel Fuel Standards Sets
Order Now

Examples of Typical Concentrations
(D6584-MIX)

Sample No. Gylcerin, mg/L Monoolein, mg/L Diolein, mg/L Triolein, mg/L
1 5 100 50 50
2 15 250 100 100
3 25 500 200 200
4 35 750 350 350
5 50 1000 500 500

(D6584-SS)

Sample No. Gylcerin, mg/L Monoolein, mg/L Diolein, mg/L Triolein, mg/L Butanetriol, mg/L Tricaprin, mg/L
1 0.5          
2   5.0        
3     5.0      
4       5.0    
5         1.0  
6           8.0
Biodiesel Sodium and Potassium

Biodiesel Sodium and Potassium
(UOP 391 or DIN EN 14538 Methods)

Cat. No. Description
UOP391 One 100 ml amber bottle containing 100 PPM each of Na and K.
UOP389 One 100 ml amber bottle containing 100 PPM each of Ca and Mg.
EN14538 One 100 ml amber bottle containing 500 PPM each of Ca, Mg, K and Na.
EN14538-2C Set of two 100 ml amber bottles consisting of: 20 PPM each of Ca, Mg, K, P and Na; and 100 PPM each of Ca, Mg, K, P and Na.
Image of Biodiesel Methanol in Fame Set products
Order Now

Biodiesel Methanol in Fame Set
(DIN EN14110 Method)

Cat. No. Description
EN14110 Methanol in FAME Set consisting of three standards and one 20 ml sealed ampoule of 2-propanol.
Image of Biodiesel Fatty Acid Methyl Esters (Fame) Sets
Order Now

Biodiesel Fatty Acid Methyl Esters (Fame) Sets
(DIN EN 14103 Method)

Cat. No. Description
EN14103 Fatty Acid Methyl Esters Set consisting of three standards and one 2 ml sealed ampoule of 2-propanol.
EN14103-IS Fatty Acid Methyl Esters Set consisting of 100 ml of methylheptadecanoate in heptane.
Image of Biodiesel Iodine Value Set
Order Now

Biodiesel Iodine Value Set
(DIN EN14214 Method)

Cat. No. Description
EN14214 Iodine Value Set consisting of 500 ml each of Iodine #50 and #200.
Image of Biodiesel Hexane Residue in Fats and Oil Set
Order Now

Biodiesel Hexane Residue in Fats and Oil Set
(ACOS Method CA 36-87)

Cat. No. Description
HEXMEO5 Hexane Residue in Fats and Oil Set consisting of five 20 ml quantities of hexane in methyloleate in sealed ampoules in concentrations of: blank, 10, 100, 500 and 1.500 mg/kg; and one 20 ml sealed ampoule of heptane as an Internal Standard.
Image of Biodiesel Simulated Distillation Set
Order Now

Biodiesel Simulated Distillation Set
(ASTM D2887)

Cat. No. Description
D2887 Diesel Reference Fuel Set consisting of a quantity of six 2 ml sealed ampoules.
Order Now
 

® SpectroCertified, SpectroStandard and Chemplex are registered trademarks of Chemplex Industries, Inc.