Biodiesel Spectrocertified® Testing Standards
Calibration standards and chemicals in accordance with the methodology indicated by ASTM D5453, D6584, D6751 and D2887; and DIN EN 14105, 14214 and 14538; and ACOS Method CA 36-87; and UOP 389 and 391 for testing biodiesel fuels.
Biodiesel Fuel Sulfur Sets
(ASTM D5453 Method)
| Cat. No. |
Description |
| S(BIO)6L |
DBS in Biodiesel Fuel Set; Low Concentration Range. 6 Standards per set; 100 ml of each. Concentrations: 0.0, 5, 10,15, 20 and 25 PPM S |
| S(BIO)6H |
DBS in Biodiesel Fuel Set; High Concentration Range. 6 Standards per set; 100 ml of each. Concentrations: 0.0, 200, 400, 600, 800 and 1000 PPM S |
Biodiesel Free and Total Glycerin Sets
(ASTM D6584 or DIN EN14105 Methods)
| Cat. No. |
Description |
| D6584-MIX |
Five standards containing the four glycerin components in pyridine in sealed ampoules as described in the methodology; one 5 ml quantity of 1000 ng/µL butanetriol Internal Standard #1 in pyridine in a sealed ampoule; one 5 ml quantity of 8000 ng/µL tricaprin Internal Standard #2 in pyridine in a sealed ampoule; one 5 ml quantity of N-methyl-N-trimethylsilyltri-fluoro aceaminde (MSTFA) silyating reagent in a capped vial; and one 250 ml amber bottle of heptane. |
| D6584-SS |
One 5 ml quantity of 500 ng/uL glycerin in pyridine in a sealed ampoule; one 5 ml quantity of 5000 ng/µL 1-Mono (cis-9-octadecanoyl)-rac-glycerol (momoolein) in pyridine in a sealed ampoule; one 5 ml quantity of 500 ng/µL 1,3-Di(cis-octadecanoyl) glycerol (dialen) in pyridine in a sealed ampoule; one 1,2,3-Tri (cis-octadecanoyl) in pyridine in a sealed ampoule; one 5 ml 1000 ng/µL butanetriol Internal Standard #1 in pyridine in a sealed ampoule; one 5 ml quantity of 8000 ng/µL tricaprin Internal Standard #2 in pyridine in a sealed ampoule; one 5 ml quantity of N-methyl-N-trimethylsilyltri-fluoro aceaminde (MSTFA) silyating reagent in a capped vial; and one 250 ml amber bottle of heptane. |
| D6584-50KIT |
Multi-Run Kit: Adequate quantities for 50 GC runs; one 5 ml sealed ampoule of Internal Standard #1; one 5 ml sealed ampoule of Internal Standard #2; and one 5 ml sealed ampoule of MSTFA. |
| D6584-100KIT |
Multi-Run Kit: Adequate quantities for 100 GC runs; one 10 ml sealed ampoule of Internal Standard #1; one 10 ml sealed ampoule of Internal Standard #2; and one 10 ml sealed ampoule of MSTFA. |
| D6584-250KIT |
Multi-Run Kit: Adequate quantities for 250 GC runs; one 25 ml sealed ampoule of Internal Standard #1; one 25 ml sealed ampoule of Standard #2; and one 25 ml sealed ampoule of MSTFA. |
| D6584-500KIT |
Multi-Run Kit: Adequate quantities for 500 GC runs; one 50 ml sealed ampoule of Internal Standard #1; one 50 ml sealed ampoule of Internal Standard #2; and one 50 ml sealed ampoule of MSTFA. |

Examples of Typical Concentrations
(D6584-MIX)
| Sample No. |
Gylcerin, mg/L |
Monoolein, mg/L |
Diolein, mg/L |
Triolein, mg/L |
| 1 |
5 |
100 |
50 |
50 |
| 2 |
15 |
250 |
100 |
100 |
| 3 |
25 |
500 |
200 |
200 |
| 4 |
35 |
750 |
350 |
350 |
| 5 |
50 |
1000 |
500 |
500 |
(D6584-SS)
| Sample No. |
Gylcerin, mg/L |
Monoolein, mg/L |
Diolein, mg/L |
Triolein, mg/L |
Butanetriol, mg/L |
Tricaprin, mg/L |
| 1 |
0.5 |
|
|
|
|
|
| 2 |
|
5.0 |
|
|
|
|
| 3 |
|
|
5.0 |
|
|
|
| 4 |
|
|
|
5.0 |
|
|
| 5 |
|
|
|
|
1.0 |
|
| 6 |
|
|
|
|
|
8.0 |
Biodiesel Sodium and Potassium
(UOP 391 or DIN EN 14538 Methods)
| Cat. No. |
Description |
| UOP391 |
One 100 ml amber bottle containing 100 PPM each of Na and K. |
| UOP389 |
One 100 ml amber bottle containing 100 PPM each of Ca and Mg. |
| EN14538 |
One 100 ml amber bottle containing 500 PPM each of Ca, Mg, K and Na. |
| EN14538-2C |
Set of two 100 ml amber bottles consisting of: 20 PPM each of Ca, Mg, K, P and Na; and 100 PPM each of Ca, Mg, K, P and Na. |
Biodiesel Methanol in Fame Set
(DIN EN14110 Method)
| Cat. No. |
Description |
| EN14110 |
Methanol in FAME Set consisting of three standards and one 20 ml sealed ampoule of 2-propanol. |
Biodiesel Fatty Acid Methyl Esters (Fame) Sets
(DIN EN 14103 Method)
| Cat. No. |
Description |
| EN14103 |
Fatty Acid Methyl Esters Set consisting of three standards and one 2 ml sealed ampoule of 2-propanol. |
| EN14103-IS |
Fatty Acid Methyl Esters Set consisting of 100 ml of methylheptadecanoate in heptane. |
Biodiesel Iodine Value Set
(DIN EN14214 Method)
| Cat. No. |
Description |
| EN14214 |
Iodine Value Set consisting of 500 ml each of Iodine #50 and #200. |
Biodiesel Hexane Residue in Fats and Oil Set
(ACOS Method CA 36-87)
| Cat. No. |
Description |
| HEXMEO5 |
Hexane Residue in Fats and Oil Set consisting of five 20 ml quantities of hexane in methyloleate in sealed ampoules in concentrations of: blank, 10, 100, 500 and 1.500 mg/kg; and one 20 ml sealed ampoule of heptane as an Internal Standard. |
Biodiesel Simulated Distillation Set
(ASTM D2887)
| Cat. No. |
Description |
| D2887 |
Diesel Reference Fuel Set consisting of a quantity of six 2 ml sealed ampoules. |
® SpectroCertified, SpectroStandard and Chemplex are registered trademarks of Chemplex Industries, Inc.