80-0252: Transfer Pipettes; 15.0mL, large bulb, narrow stem; 15.5cm long; 250/Pkg

$45.00
Availability: In stock
SKU
80-0252
  • Buy 10 for $41.00 each and save 9%

Chemplex® transfer pipettes are used to conveniently fill Chemplex® XRF Sample Cups with consistent volumes of samples and standards to their near volumetric capacities, minimize or eliminate any discrepancies in x-ray data attributed to dissimilar volumes, avoid spillage and prevent cross-contamination possibilities plus they are affordably priced for disposability.

Features

Transfer liquid samples into sample cups

Equal sample volumes per sample cup

Avoid spillages and contamination issues

Integrated bulb and stem

Unbreakable polyethene

Affordably priced for disposability (elmininate contamination)

Packaging

Several hunderd /pkg ( size dependent)

Chemplex® transfer pipettes are used to conveniently fill Chemplex® XRF Sample Cups with consistent volumes of samples and standards to their near volumetric capacities, minimize or eliminate any discrepancies in x-ray data attributed to dissimilar volumes, avoid spillage and prevent cross-contamination possibilities plus they are affordably priced for disposability.

For general laboratory applications, transfer pipettes find their greatest utility in transferring innumerable types of liquid chemicals into other laboratory containers. With Chemplex® transfer pipettes this procedure is greatly simplified and performed with ease, reasonable degrees of accuracy, safety, no contamination and economically priced for disposability.

Note: Transfer pipettes are non-sterile and sold only in complete packages. As a reminder, be certain to order the number of pipettes to correspond to the number of sample cups to be filled; Chemplex® XRF Sample Cups are packaged in quantities of 100 sets.

More Information

How to Use Transfer Pipettes: Transfer pipettes are fabricated from unbreakable polyethylene; the bulbs are integrated with the stems as single units. Squeeze the pipette bulb to expel the air and insert the tip into the sample. Release the applied hand pressure to the bulb until the sample is completely drawn up. Insert the tip of the filled pipette into the sample cup and gently squeeze the bulb to dispense the entire sample. Repeat the procedure in instances that require additional draws to fill the sample cup as tabulated in the Pipette Selection Chart.

Viscosity Considerations: The transfer of viscous substances such as petroleum, waste oils, paint and slurries is more expeditiously handled with large pipette tips. Most other materials with high fluidity characteristics are served best with pipettes having fine tips. Empirical testing is suggested for confirmation of convenience.

Disposability: Transfer pipettes are intended to be used once, except for multiple sequential draws, to avert cross-contamination possibilities. Dispose used pipettes properly in accordance with local and other accepted authorities and procedures.

Easy Selection Process: Selection of the most appropriate transfer pipette is correlated to the volumetric capacities of Chemplex® XRF sample cups and the dispensing volumes of pipettes. Simply refer the Chemplex® sample cup catalog number to the pipette catalog number(s). The number of draws required to fill a sample cup have been pre-determined and a choice of tips and style sare provided.

Sample Cup

Cat. No.

Pipette

Cat. No.

Capacity,

mL

Number

Draws

Sample Cup

Cat. No.

Pipette

Cat. No.

Capacity,

mL

Number

Draws

1060

80-0204

80-0234

80-0691

9

2

1850

80-0204

80-0234

80-0691

13

3

1065

80-0252

8

1

1930

1930-SE

80-0252

8

1

1070

80-0204

80-0234

80-0691

13

3

1940

80-0252

15

2

1075

80-0204

80-0234

80-0691

13

3

1940L

80-0252

25

3

1080

80-0252

15

2

1935-OX

80-0252

17

2

1083

80-0204

80-0234

80-0691

12

3

2132

80-0204

80-0234

80-0691

9

2

1085

80-0204

80-0234

80-0691

12

3

2135

80-0204

80-0234

80-0691

11

3

1095

80-0252

30

4

2140

80-0252

19

3

1330

1330-SE

80-0252

7

1

2143

80-0252

19

3

1340

80-0204

80-0234

80-0691

12

3

2144

80-0252

19

3

1430

1430-SE

80-0204

80-0234

80-0691

9

2

2145

80-0252

22

3

1440

80-0252

15

2

2146

80-0252

22

3

1440L

80-0252

25

3

P2

80-0252

22

3

1530

1530-SE

80-0204

80-0234

80-0691

9.5

2

2195

80-0252

22

3

1540

80-0252

16

2

3106

80-0225

0.2

1

1730

1730-SE

80-0252

7

1

3110

80-0225

0.5

1

1740

80-0204

80-0234

80-0691

11.5

3

3115

80-0225

1

1

1830

1830-SE

80-0252

7

1

3120

80-0225

5.5

2

1840

80-0204

80-0234

80-0691

12

3

3130

3132

3135

80-0225

1

1/3

Yes
Write Your Own Review
You're reviewing:80-0252: Transfer Pipettes; 15.0mL, large bulb, narrow stem; 15.5cm long; 250/Pkg
Your Rating